TH COMMUNICATION SDN. BHD.
27, Jalan Badik 17,
Taman Puteri Wangsa,
81800 Ulu Tiram,
Johor, Malaysia.
27, Jalan Badik 17,
Taman Puteri Wangsa,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8676767
+607-8673811
+607-8673811
+607-8673812
thcomwong
PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable - Blue
| Previous | 1 / 33 | Next |
RM 0.00
PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable - Blue
Product Code: 1101-04045DINTEK PowerMAX500TM unshielded Cat.6 / Class E U/UTP PVC cable
is guaranteed to exceed Cat.6 specifications as set down in ANSI/TIA and ISO/IEC standards.
Our PowerMAX500TM solution comprises unshielded Cat.6
component compliant patch panels, keystones, and patch cords.
When combined with DINTEK’s unshielded Cat.6 / Class E U/UTP PVC cable,
an end-to-end channel exists that maximizes data throughput and provides headroom
for future technologies operating to, and beyond 1 Gigabit Ethernet.

Features & Applications
- Horizontal and backbone cable
- 1000BASE-TX Gigabit Ethernet / 1000BASE-T Gigabit Ethernet
- 100BASE-TX Fast Ethernet / 10BASE-TX Ethernet
- 100 Mbps TP-PMD / 100VG-AnyLAN
- Broadband Video / Voice / T1 / ISDN
- 10 Gigabit (500Mhz) Transmission up to length of 70Mtrs
Standards Conformance
- Performance - ANSI/TIA 568.2-D Cat.6 / ISO/IEC 11801
- Structural - EN 13501-6:2014 | IEC 61156-5 | EN 50288-6-1
- PoE capability - IEEE 802.3bt level 3 & 4 (PoE++ & 4PPoE)
- Environmental - Conforms to RoHS and REACH Directives
- Flame testing - EN 60332-1-2
Independent Verified Certifications
- ETL Certification according to ANSI / TIA-568.2-D Cat.6
- UL Cable Fire Rating - CM as per UL 444
Features
- Capable of handling the latest versions of Power over Ethernet
- Conductor sizes for PowerMAX500TM Cat.6 set at 23AWG
- PVC jacketed 4 pair telecommunications cable
- Successful transmission at 500Mhz up to a length of 70Mtrs
- EZI-Pull 305Mtr Box for trouble free installation

Performance Statistics
| Frequency Mhz | Insertion Loss dB/100mtrs | NEXT (dB) | Return Loss (dB) |
| 1 | 2 | 74.3 | 20 |
| 4 | 3.8 | 65.3 | 23 |
| 10 | 6 | 59.3 | 25 |
| 16 | 7.6 | 56.3 | 25 |
| 20 | 8.5 | 54.8 | 25 |
| 31.25 | 10.7 | 51.9 | 23.6 |
| 62.5 | 15.4 | 47.4 | 21.5 |
| 100 | 19.8 | 42.4 | 20.1 |
| 200 | 29 | 39.8 | 18 |
| 250 | 32.8 | 38.3 | 17.3 |
Meets and exceeds values above based on 100 meters (328 ft.) at 20°C as per
ANSI/TIA-568-D.2 for Cat.6 / ISO/IEC 11801 Class E / EN 50173.
DINTEK PowerMAX500TM Cat.6 / Class E cables have additionally been tested up to 500Mhz
and have shown performance results that allow for successful transmission of 10 Gigabit Ethernet up to 70Mtrs.
| Ordering Information | |||||
| Product Number | Product Name | Jacket Rating | Color | Length Qty | Qty / Pallet |
| 1101-04045 | PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable | CM | Blue | 305Mtr Box | 24 or 36 |
Technical Specifications
| Construction | |
| Conductor | |
| Material | Pure Annealed Copper |
| Wire Size | 23AWG |
| Strand Type | Solid Core |
| No. Of Pairs | 4P |
| Insulation | |
| Material | Polyethylene |
| Thickness | 0.21mm ± 0.01mm |
| Diameter | 0.98mm ± 0.05mm |
| Colors | Blue/White | Orange/White | Green/White | Brown/White |
| Pair Foil Wrap | None |
| Jacket | |
| Material | PVC |
| Thickness | 0.5 mm ± 0.05mm |
| Diameter | 5.70mm ± 0.3mm |
| Color | Blue |
| Jacket Rating | CM |
| Foil Shield | None |
| Braided Shield | None |
Physical Ranges
| Jacket | |
| Cold Bend Test | -20 ± 2°C x 4hrs no crack |
| Min. Bending Radius | Min. 4 x Cable Diameter |
| Max. Pulling Tension | 110N |
| Installation Temperature | 0°C to +50°C |
| Operating Temperature | -20°C to +60°C |
| Electrical | |
| Conductor Resistance | Max. 9.38 Ω/100m at 20¡æ |
| DC Resistance Unbalance | Max. 2% at 20°C |
| Pair-to-Ground Capacitance Unbalance | Max. 1600 pF/km at 1 kHz |
| Dielectric Strength of Insulation | DC 1 kV for 1 min |
| Insulation Resistance Test (500V) | Min. 5000 MΩ/Km at 20°C |
| Mutual Capacitance | Max. 5600 pF/100m at 1 kHz |
| Impedance 1~250MHz | 100Ω ± 15% |
| Nominal Velocity Of Propagation | 67% |